Specifications
| Model | MG010 | MG020 | MG050 | MG100 | MG200 |
|---|---|---|---|---|---|
| Rated tension (N) | 100 | 200 | 500 | 1000 | 2000 |
| Roll displacement (μm=N) | 2.63 | 1.23 | 0.48 | 0.20 | 0.11 |
| Allowable roll weight (kg) | 10 | 20 | 50 | 100 | 200 |
| Allowable overload (N) | Ten times rated load | ||||
| Unit weight (kg) | 1.5 | 2.6 | |||
| Tension resultant direction | Forward or reverse possible | ||||
| Mounting angle | Any desired angle | ||||
| Supply voltage | DC+6V | ||||
| Ambient temperature | -10 to +60℃ | ||||
| Applicable bearings | UCP201 to 204 * UCP205 may also be employed when optional pillow-mounting | UCP201 to 204 pillow-employed when optional pillowmounting brackets (MD0178.0-12P) are used. | |||
| Note 1. Figures for rated tension and allowable roll weight are for double-sided detection. For single detection the above figures should be halved. 2. A 5m cable with connectors for connection to an amplifier is supplied. | |||||